Rosemount™ 644 temperature transmitter

Rosemount™ 644 temperature transmitter

Rosemount 644 temperature transmitters are versatile and available using HART™, FOUNDATION™ Fieldbus or PROFIBUS™ protocols, with top, field or rail mount styles and multiple housing options. By adding a Local Operator Interface (LOI), the transmitter configuration can be updated in the field without tools. The transmitter also includes diagnostic functions such as Hot Backup™, sensor drift warning and thermocouple performance degradation to meet different application requirements.

Rosemount™ 644 Temperature Transmitter Specifications:

1. Inputs Support universal sensor inputs (RTD, T/C, mV, ohms) for single or dual sensor assemblies
2. Output signal 4-20 mA /HART™ protocol, FOUNDATION™ fieldbus protocol, PROFIBUS™ PA protocol
3. Housing field mount, DIN A head mount or rail mount
4. Display/Interface LCD display with Local Operator Interface (LOI) LCD display
5. Diagnostics Basic diagnostics, Hot Backup™ function, sensor drift warning, thermocouple aging, min/Max tracking
6. Calibration option transducer-sensor matching (Callender-Van. Doussen constant), 5- point calibration
7. Certification/Certification Independent third party certified to SIL 2/3 according to IEC 61508, hazardous Places, ship type.

product-800-800

product-1200-1600

Rosemount™ 644 Temperature Transmitter Features:

1. A versatile temperature transmitter with HART™, FOUNDATION™ Fieldbus or PROFIBUS™ protocols.
2. A variety of housing selection, to achieve a variety of installation configurations, including top, field or rail installation.
3. The LOI option eliminates the need for special configuration tools (e.g., field hand operators) for ease of use.
4. The transmitter - sensor meets the Callendar-Van Dusen constant matching, reducing the total measurement error.
5. The Hot Backup™ function and sensor drift warning feature dual sensors to ensure measurement integrity.
6. The thermocouple aging diagnosis function can monitor the health of the thermocouple and prevent the failure caused by aging.
7. Minimum and maximum temperature tracking can monitor temperature limits for easy troubleshooting.
8. The device dashboard can be used as a concise interface to simplify device configuration and perform diagnostic troubleshooting.

product-1-1

Contact Us:

Shaaxi ZYY is an expert instrument organization gaining practical experience in the deals of top brands like Emerson Rosemount, Yokogawa, Endress+Hauser (E+H), Fisher, Honeywell, ABB, Siemens, and that's only the tip of the iceberg. With more than 10 years of involvement as a provider, we offer an extensive variety of item models and are focused on giving proficient answers for our clients. For more item evaluating data or to talk about your particular requirements, please contact us at lm@zyyinstrument.com. We look forward to serving you.

YOU MAY LIKE

Rosemount 3051CD Coplanar Pressure Transmitter

Rosemount 3051CD Coplanar Pressure Transmitter

The Rosemount 3051CD differential pressure transmitter is the smart differential pressure transmitter in the Rosemount transmitter. The Rosemount 3051 pressure transmitter offers unmatched operational performance, the flexible CoPlanarTM platform, and can be upgraded. The performance specifications of the new Rosemount 3051 transmitter guarantee accuracy and stability under different working conditions.
View More
Rosemount™ 3144P temperature transmitter

Rosemount™ 3144P temperature transmitter

Rosemount 3144P temperature transmitter provides you with industry-leading temperature measurements with accuracy, stability and reliability. The transmitter's dual chamber housing ensures reliability and advanced diagnostics to keep your measuring points up and running. The transmitter combines Rosemount X-well™ technology with the Rosemount 0085 clamp sensor to accurately measure process temperature, eliminating the need for hot tubing or process penetration.
View More
Rosemount 248

Rosemount 248

Class A accuracy (optional)
Various housing and connector options
North American certification
One-year stability guarantee
Open/short sensor diagnostics
Transmitter-sensor meets Callendar-Van Dusen constant matching
View More
Yokogawa Temperature Transmitter YTA710

Yokogawa Temperature Transmitter YTA710

Supports input of thermocouple, thermal resistance, DC voltage or resistance signals.
Converted to 4-20 mA DC signal or fieldbus signal output.
It is divided into HART communication type and FOUNDATIONTM fieldbus communication type.
The HART communication type complies with SIL2 safety level.
View More
Yokogawa Temperature Transmitter Yta610

Yokogawa Temperature Transmitter Yta610

Supports the input of thermocouple, thermal resistance, DC voltage, or resistance signals.
Converted to 4-20 mA DC signal or fieldbus signal output.
It is divided into HART communication type and FOUNDATIONTM fieldbus communication type.
The HART communication type complies with the SIL2 safety level.
View More
Yokogawa Temperature Transmitter YTA110

Yokogawa Temperature Transmitter YTA110

Supports input of thermocouple, thermal resistance, DC voltage or resistance signals.
Converted to 4-20 mA DC signal or fieldbus signal output.
It is divided into HART communication type and FOUNDATIONTM fieldbus communication type.
The HART communication type complies with SIL2 safety level.
View More
Rosemount 3051l Liquid Level Transmitter

Rosemount 3051l Liquid Level Transmitter

Installation: The product can be installed directly or used with Tuned-System™ components.
Warranty: Offers a 5-year limited warranty.
Maximum Working Pressure: The product can handle up to 300 psi (20.68 bar).
Temperature Range: It operates within a temperature range from -105°C (-157°F) to 205°C (401°F), depending on the fill fluid used.
Communication Protocols: Compatible with various protocols including 4-20 MA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS® PA, and 1-5 V low power HART®.
Seal System: Features a direct mounting system.
View More
Rosemount 214c Temperature Sensor

Rosemount 214c Temperature Sensor

Class A accuracy (optional)
Various housing and connector options
North American certification
One-year stability guarantee
Open/short sensor diagnostics
Transmitter-sensor meets Callendar-Van Dusen constant matching
View More